<?xml version="1.0"?>
<Articles JournalTitle="Frontiers in Dentistry">
  <Article>
    <Journal>
      <PublisherName>Tehran University of Medical Sciences</PublisherName>
      <JournalTitle>Frontiers in Dentistry</JournalTitle>
      <Issn>2676-296X</Issn>
      <Volume>17</Volume>
      <Issue>0</Issue>
      <PubDate PubStatus="epublish">
        <Year>2020</Year>
        <Month>12</Month>
        <Day>13</Day>
      </PubDate>
    </Journal>
    <title locale="en_US">In Vitro Bacterial Leakage at the Implant-Abutment Connection of Two Dental Implant Systems with Internal Connection</title>
    <FirstPage>3333</FirstPage>
    <LastPage>3333</LastPage>
    <AuthorList>
      <Author>
        <FirstName>Azadeh</FirstName>
        <LastName>Khajavi</LastName>
        <affiliation locale="en_US">Department of Prosthodontics, School of Dentistry, Qazvin University of Medical Sciences, Qazvin, Iran</affiliation>
      </Author>
      <Author>
        <FirstName>Shabnam</FirstName>
        <LastName>Mohseni</LastName>
        <affiliation locale="en_US">Student Research Committee, Qazvin University of Medical Sciences, Qazvin, Iran</affiliation>
      </Author>
      <Author>
        <FirstName>Amir</FirstName>
        <LastName>Peymani</LastName>
        <affiliation locale="en_US">Medical Microbiology Research Center, Qazvin University of Medical Sciences, Qazvin, Iran</affiliation>
      </Author>
      <Author>
        <FirstName>Mehrak</FirstName>
        <LastName>Amjadi</LastName>
        <affiliation locale="en_US">Department of Prosthodontics, Dental Caries Prevention Research Center, Qazvin University of Medical Sciences, Qazvin, Iran</affiliation>
      </Author>
    </AuthorList>
    <History>
      <PubDate PubStatus="received">
        <Year>2019</Year>
        <Month>10</Month>
        <Day>23</Day>
      </PubDate>
      <PubDate PubStatus="accepted">
        <Year>2020</Year>
        <Month>08</Month>
        <Day>31</Day>
      </PubDate>
    </History>
    <abstract locale="en_US">Objectives: Bacterial leakage at the implant-abutment interface is one of the main causes of peri-implant inflammation. One of the factors that influences bacterial leakage is the structural design of the interface. Considering the limited studies that have examined slip-joint connections, a comparative study of bacterial leakage was performed on two different systems namely Zimmer (Tapered Screw-Vent, Zimmer Dental) with slip-joint connection and Argon (Konus K3pro, Argon Implants) with conical connection.
Materials and Methods: Twenty-two implants were selected in 2 groups (11 Zimmer with slip-joint connection, and 11 Argon with conical connection) with similar platforms. Escherichia coli (E. coli) suspension (2 &#x3BC;L) was pipetted into the internal lumen of implants. The abutments were screwed onto the implants with a closing torque of 30 Ncm. The assemblies were placed in culture broth for 6, 24, 48 and 72 h, and 7 and 14 days. The colonies were counted and analyzed by the Mann-Whitney test (a=0.05).
Results: Microleakage was observed in 20% of the samples of conical connection group after 6 h to 2 days, and in 50% of the samples in slip-joint connection group after 3 to 7 days. There was a significant difference in bacterial leakage rate between the two implant groups (P&lt;0.001) but no significant difference was seen in bacterial leakage over time (P&gt;0.05).
Conclusion: Type of connection had a significant effect on bacterial leakage, but the rate of bacterial leakage did not significantly change over time.</abstract>
    <web_url>https://fid.tums.ac.ir/index.php/fid/article/view/3333</web_url>
    <pdf_url>https://fid.tums.ac.ir/index.php/fid/article/download/3333/1827</pdf_url>
  </Article>
</Articles>