<?xml version="1.0"?>
<Articles JournalTitle="Frontiers in Dentistry">
  <Article>
    <Journal>
      <PublisherName>Tehran University of Medical Sciences</PublisherName>
      <JournalTitle>Frontiers in Dentistry</JournalTitle>
      <Issn>2676-296X</Issn>
      <Volume>22</Volume>
      <Issue>0</Issue>
      <PubDate PubStatus="epublish">
        <Year>2025</Year>
        <Month>02</Month>
        <Day>18</Day>
      </PubDate>
    </Journal>
    <title locale="en_US">Dimensional Stability and Accuracy of Silicone Impression Materials after Ozone Water Disinfection: An In Vitro Study</title>
    <FirstPage>4277</FirstPage>
    <LastPage>4277</LastPage>
    <AuthorList>
      <Author>
        <FirstName>Abinaya</FirstName>
        <LastName>Kutralanathan</LastName>
        <affiliation locale="en_US">Department of Prosthodontics and Crown and Bridge, SRM Dental College, Bharathi Salai, Ramapuram, Chennai,  Tamil Nadu, India</affiliation>
      </Author>
      <Author>
        <FirstName>Ahila</FirstName>
        <LastName>Singaravel Chidambaranathan</LastName>
        <affiliation locale="en_US">Department of Prosthodontics and Crown and Bridge, SRM Dental College, Bharathi Salai, Ramapuram, Chennai,  Tamil Nadu, Indi</affiliation>
      </Author>
      <Author>
        <FirstName>Muthukumar</FirstName>
        <LastName>Balasubramaniam</LastName>
        <affiliation locale="en_US">Department of Prosthodontics and Crown and Bridge, SRM Dental College, Bharathi Salai, Ramapuram, Chennai,  Tamil Nadu, India</affiliation>
      </Author>
    </AuthorList>
    <History>
      <PubDate PubStatus="received">
        <Year>2021</Year>
        <Month>11</Month>
        <Day>18</Day>
      </PubDate>
      <PubDate PubStatus="accepted">
        <Year>2022</Year>
        <Month>12</Month>
        <Day>21</Day>
      </PubDate>
    </History>
    <abstract locale="en_US">Objectives: This study evaluated the effect of ozone water disinfection on dimensional stability and accuracy of silicone impression materials.
&#xD;

Materials and Methods: According to ISO-4823, a stainless-steel die was fabricated for this in vitro study. Three horizontal parallel lines, namely x, y, and z (25, 50, and 75&#xB5;m in width and 25mm in length) running perpendicular to two vertical lines, namely D1 and D2 (0.075&#xB1;0.008mm wide), were created on the superior surface of the die. Group A served as the control group with no disinfection. Disinfection was performed with 2% glutaraldehyde in group B, 5.25% sodium hypochlorite in group C, and ozone water in group D for 10 minutes. Totally, 60 samples were fabricated. The silicone impression samples were allowed to polymerize in a thermostatically controlled water bath at 35&#xB1;1&#xBA;C for 10 minutes. The dimensional stability and accuracy of the silicone impression samples were evaluated by using a video measuring microscope and an optical microscope. Data were analyzed by two-way ANOVA followed by post-hoc analysis with the Scheffe test (alpha=0.05).
&#xD;

Results: The highest dimensional stability (25.01mm) and accuracy (25.02&#xB5;m) were seen in addition silicone putty and light body impression with ozone water disinfection, and the lowest parameters were seen in condensation silicon putty and light body disinfected with 2% glutaraldehyde (24.87mm and 24.88 &#xB5;m, respectively); this difference was statistically significant (P&lt;0.001).
&#xD;

Conclusion: Ozone water disinfection caused minimal changes in dimensional stability and accuracy when compared to 2% glutaraldehyde and 5.25% sodium hypochlorite disinfection</abstract>