<?xml version="1.0"?>
<Articles JournalTitle="Frontiers in Dentistry">
  <Article>
    <Journal>
      <PublisherName>Tehran University of Medical Sciences</PublisherName>
      <JournalTitle>Frontiers in Dentistry</JournalTitle>
      <Issn>2676-296X</Issn>
      <Volume>11</Volume>
      <Issue>2</Issue>
      <PubDate PubStatus="epublish">
        <Year>2014</Year>
        <Month>04</Month>
        <Day>15</Day>
      </PubDate>
    </Journal>
    <title locale="en_US">Implant Surface Temperature Changes during Er:YAG Laser Irradiation with Different Cooling Systems.</title>
    <FirstPage>210</FirstPage>
    <LastPage>5</LastPage>
    <AuthorList>
      <Author>
        <FirstName>Abbas</FirstName>
        <LastName>Monzavi</LastName>
        <affiliation locale="en_US">Associate Professor, Laser Research Center of Dentistry (LRCD), School of Dentistry, Tehran University of Medical Sciences, Tehran, Iran.</affiliation>
      </Author>
      <Author>
        <FirstName>Sima</FirstName>
        <LastName>Shahabi</LastName>
        <affiliation locale="en_US">Associate Professor, Laser Research Center of Dentistry (LRCD), School of Dentistry, Tehran University of Medical Sciences, Tehran, Iran.</affiliation>
      </Author>
      <Author>
        <FirstName>Reza</FirstName>
        <LastName>Fekrazad</LastName>
        <affiliation locale="en_US">Associate Professor, Laser Research Center in Medical Sciences (LRCMS), AJA University of Medical Sciences-Laser Research Center of Dentistry (LRCD), School of Dentistry, Tehran University of Medical Sciences, Tehran, Iran.</affiliation>
      </Author>
      <Author>
        <FirstName>Roohollah</FirstName>
        <LastName>Behruzi</LastName>
        <affiliation locale="en_US">Postgraduate student, department of endodontics, School of Dentistry, Tehran University of Medical Sciences, Tehran, Iran.</affiliation>
      </Author>
      <Author>
        <FirstName>Nasim</FirstName>
        <LastName>Chiniforush</LastName>
        <affiliation locale="en_US">PhD Candidate of Laser Dentistry, Laser Research Center of Dentistry (LRCD), School of Dentistry, Tehran University of Medical Sciences, Tehran, Iran.</affiliation>
      </Author>
    </AuthorList>
    <History>
      <PubDate PubStatus="received">
        <Year>2015</Year>
        <Month>10</Month>
        <Day>16</Day>
      </PubDate>
    </History>
    <abstract locale="en_US">Peri-implantitis is one of the most common reasons for implant failure. Decontamination of infected implant surfaces can be achieved effectively by laser irradiation; although the associated thermal rise may cause irreversible bone damage and lead to implant loss. Temperature increments of over 10&#xBA;C during laser application may suffice for irreversible bone damage.The purpose of this study was to evaluate the temperature increment of implant surface during Er:YAG laser irradiation with different cooling systems.Three implants were placed in a resected block of sheep mandible and irradiated with Er:YAG laser with 3 different cooling systems namely water and air spray, air spray alone and no water or air spray. Temperature changes of the implant surface were monitored during laser irradiation with a K-type thermocouple at the apical area of the fixture.In all 3 groups, the maximum temperature rise was lower than 10&#xB0;C. Temperature changes were significantly different with different cooling systems used (P</abstract>
    <web_url>https://fid.tums.ac.ir/index.php/fid/article/view/517</web_url>
    <pdf_url>https://fid.tums.ac.ir/index.php/fid/article/download/517/493</pdf_url>
  </Article>
</Articles>
