<?xml version="1.0"?>
<Articles JournalTitle="Frontiers in Dentistry">
  <Article>
    <Journal>
      <PublisherName>Tehran University of Medical Sciences</PublisherName>
      <JournalTitle>Frontiers in Dentistry</JournalTitle>
      <Issn>2676-296X</Issn>
      <Volume>10</Volume>
      <Issue>6</Issue>
      <PubDate PubStatus="epublish">
        <Year>2013</Year>
        <Month>12</Month>
        <Day>15</Day>
      </PubDate>
    </Journal>
    <title locale="en_US">Comparative evaluation of physical properties of four tissue conditioners relined to modeling plastic material.</title>
    <FirstPage>506</FirstPage>
    <LastPage>15</LastPage>
    <AuthorList>
      <Author>
        <FirstName>Abbas</FirstName>
        <LastName>Monzavi</LastName>
        <affiliation locale="en_US">Associate Professor, Laser Research Center of Dentistry, Dentistry Research Institute, Department of Prosthodontics, Tehran University of Medical Sciences, Tehran, Iran.</affiliation>
      </Author>
      <Author>
        <FirstName>Hakimeh</FirstName>
        <LastName>Siadat</LastName>
        <affiliation locale="en_US">Associate Professor, Dental Implant Research Center, Dentistry Research Institute, Department of Prosthodontics, Tehran University of Medical Sciences, Tehran, Iran.</affiliation>
      </Author>
      <Author>
        <FirstName>Mohammad</FirstName>
        <LastName>Atai</LastName>
        <affiliation locale="en_US">Professor, Iran Polymer and Petrochemical Institute (IPPI), Tehran, Iran.</affiliation>
      </Author>
      <Author>
        <FirstName>Marzieh</FirstName>
        <LastName>Alikhasi</LastName>
        <affiliation locale="en_US">Associate Professor, Dental Research Center, Dentistry Research Institute, Department of Prosthodontics, Tehran University of Medical Sciences, Tehran, Iran.</affiliation>
      </Author>
      <Author>
        <FirstName>Vahideh</FirstName>
        <LastName>Nazari</LastName>
        <affiliation locale="en_US">Resident of Prosthodontics, Tehran University of Medical Sciences, Tehran, Iran.</affiliation>
      </Author>
      <Author>
        <FirstName>Sadigheh</FirstName>
        <LastName>Sheikhzadeh</LastName>
        <affiliation locale="en_US">Resident of Orthodontics, Tehran University of Medical Sciences, Tehran, Iran.</affiliation>
      </Author>
    </AuthorList>
    <History>
      <PubDate PubStatus="received">
        <Year>2015</Year>
        <Month>10</Month>
        <Day>16</Day>
      </PubDate>
    </History>
    <abstract locale="en_US">Little is known about the interaction of tissue conditioners and modeling plastics. This study evaluates the influence of a variety of commercial tissue conditioners on alteration of viscoelastic properties of modeling plastics.In this in vitro study, the dynamic viscoelastic properties of four commercially available tissue conditioners (TC), Visco-gel (VG), GC Soft-Liner (SL), FITT (FT), and Coe Comfort (CC), relined to modeling plastics with a thickness of 2mm were evaluated after 1 and 7 days of water immersion with the use of storage modulus, loss modulus, and tan delta parameters. Values for these three parameters for each tissue conditioner were statistically analyzed by Kruskal Wallis and Mann Whitney tests with P value sets at</abstract>
    <web_url>https://fid.tums.ac.ir/index.php/fid/article/view/591</web_url>
    <pdf_url>https://fid.tums.ac.ir/index.php/fid/article/download/591/566</pdf_url>
  </Article>
</Articles>
