<?xml version="1.0"?>
<Articles JournalTitle="Frontiers in Dentistry">
  <Article>
    <Journal>
      <PublisherName>Tehran University of Medical Sciences</PublisherName>
      <JournalTitle>Frontiers in Dentistry</JournalTitle>
      <Issn>2676-296X</Issn>
      <Volume>14</Volume>
      <Issue>1</Issue>
      <PubDate PubStatus="epublish">
        <Year>2017</Year>
        <Month>02</Month>
        <Day>15</Day>
      </PubDate>
    </Journal>
    <title locale="en_US">Effect of Polyvinyl Siloxane Viscosity on Accuracy of Dental Implant Impressions</title>
    <FirstPage>40</FirstPage>
    <LastPage>47</LastPage>
    <Language>EN</Language>
    <AuthorList>
      <Author>
        <FirstName>Ahmad</FirstName>
        <LastName>Ghahremanloo</LastName>
        <affiliation locale="en_US">Associate Professor of Prosthodontics Department, Mashhad Dental School, Mashhad University of Medical Sciences, Mashhad, Iran</affiliation>
      </Author>
      <Author>
        <FirstName>Mahdieh</FirstName>
        <LastName>Seifi</LastName>
        <affiliation locale="en_US">Assistant Professor of Prosthodontics Department, Mashhad Dental School, Mashhad University of Medical Sciences, Mashhad, Iran</affiliation>
      </Author>
      <Author>
        <FirstName>Jalil</FirstName>
        <LastName>Ghanbarzade</LastName>
        <affiliation locale="en_US">Associate Professor of Prosthodontics Department, Mashhad Dental School, Mashhad University of Medical Sciences, Mashhad, Iran</affiliation>
      </Author>
      <Author>
        <FirstName>Seyyed Mohammad</FirstName>
        <LastName>Abrisham</LastName>
        <affiliation locale="en_US">Assistant Professor of Prosthodontics Department, Yazd Dental School, Shahid Sadoughi University of Medical Sciences, Yazd, Iran</affiliation>
      </Author>
      <Author>
        <FirstName>Rashid Abdolah</FirstName>
        <LastName>Javan</LastName>
        <affiliation locale="en_US">Statistical Advisor, Mashhad Dental School, Mashhad University of Medical Sciences, Mashhad, Iran</affiliation>
      </Author>
    </AuthorList>
    <History>
      <PubDate PubStatus="received">
        <Year>2015</Year>
        <Month>11</Month>
        <Day>03</Day>
      </PubDate>
      <PubDate PubStatus="accepted">
        <Year>2016</Year>
        <Month>10</Month>
        <Day>25</Day>
      </PubDate>
    </History>
    <abstract locale="en_US">Objectives: The aim of this study was to compare the accuracy of dental implant impressions obtained by a combination of different impression techniques and viscosities of polyvinyl siloxane (PVS).
Materials and Methods: Four parallel fixtures were placed between mental foramina in a master model of lower dental arch. Three different viscosities (putty/light body, medium body/light body, and monophase: heavy body) and direct and indirect techniques (six groups) were used, and seven impressions were obtained from each group (n=42). To measure the accuracy of impressions, drift, horizontal, and vertical angles of the implants, as well as the hex rotation of the implants in casts were evaluated using a digitizer device (1&#x3BC;m accuracy), in comparison with master arch. Data were analyzed using five-factor two-way ANOVA and Tukey&#x2019;s post-hoc test.
Results: The accuracy of impressions was assessed and the results showed that direct technique was not significantly different from indirect technique (P&gt;0.05). Also, there were no significant differences between the mentioned viscosities except for the horizontal angle (P=0.006).
Conclusions: Viscosity of impression materials is of high significance for the accuracy of dental impressions.
&#xD;

&#xA0;</abstract>
    <web_url>https://fid.tums.ac.ir/index.php/fid/article/view/830</web_url>
    <pdf_url>https://fid.tums.ac.ir/index.php/fid/article/download/830/933</pdf_url>
  </Article>
</Articles>