<?xml version="1.0"?>
<Articles JournalTitle="Frontiers in Dentistry">
  <Article>
    <Journal>
      <PublisherName>Tehran University of Medical Sciences</PublisherName>
      <JournalTitle>Frontiers in Dentistry</JournalTitle>
      <Issn>2676-296X</Issn>
      <Volume>13</Volume>
      <Issue>6</Issue>
      <PubDate PubStatus="epublish">
        <Year>2017</Year>
        <Month>01</Month>
        <Day>11</Day>
      </PubDate>
    </Journal>
    <title locale="en_US">Comparison of Bond Strength of Metal and Ceramic Brackets Bonded with Conventional and High-Power LED Light Curing Units</title>
    <FirstPage>423</FirstPage>
    <LastPage>430</LastPage>
    <Language>EN</Language>
    <AuthorList>
      <Author>
        <FirstName>Javad</FirstName>
        <LastName>Chalipa</LastName>
        <affiliation locale="en_US">Assistant Professor, Dental Research Center, Dentistry Research Institute, Tehran University of Medical Sciences, Tehran, Iran; Department of Orthodontics, School of Dentistry, Tehran University of Medical Sciences, Tehran, Iran</affiliation>
      </Author>
      <Author>
        <FirstName>Yasamin</FirstName>
        <LastName>Farajzadeh Jalali</LastName>
        <affiliation locale="en_US">Assistant Professor, Department of Orthodontics, School of Dentistry, Ilam University of Medical Science, Ilam, Iran</affiliation>
      </Author>
      <Author>
        <FirstName>Fatemeh</FirstName>
        <LastName>Gorjizadeh</LastName>
        <affiliation locale="en_US">Assistant Professor, Department of Orthodontics, School of Dentistry, Yasuj University of Medical Science, Yasuj, Iran</affiliation>
      </Author>
      <Author>
        <FirstName>Pedram</FirstName>
        <LastName>Baghaeian</LastName>
        <affiliation locale="en_US">Private Practice Tehran University of Medical Sciences, Tehran, Iran</affiliation>
      </Author>
      <Author>
        <FirstName>Mohammad Hashem</FirstName>
        <LastName>Hoseini</LastName>
        <affiliation locale="en_US">Assistant Professor, Dental Research Center, Dentistry Research Institute, Tehran University of Medical Sciences, Tehran, Iran; Department of Orthodontics, School of Dentistry, Tehran University of Medical Sciences, Tehran, Iran</affiliation>
      </Author>
      <Author>
        <FirstName>Omid</FirstName>
        <LastName>Mortezai</LastName>
        <affiliation locale="en_US">Assistant Professor, Department of Orthodontics, Qazvin University of Medical Sciences, Qazvin, Iran</affiliation>
      </Author>
    </AuthorList>
    <History>
      <PubDate PubStatus="received">
        <Year>2015</Year>
        <Month>12</Month>
        <Day>27</Day>
      </PubDate>
      <PubDate PubStatus="accepted">
        <Year>2016</Year>
        <Month>06</Month>
        <Day>19</Day>
      </PubDate>
    </History>
    <abstract locale="en_US">Objectives: The aim of this study was to evaluate the effect of conventional and high-power light emitting diode (LED) light curing units on shear bond strength (SBS) of metal and ceramic brackets to tooth surface.
Materials and Methods: Forty sound bovine maxillary central incisors were used for the study. The teeth were divided into four groups (n=10). Teeth surfaces were etched with 37% phosphoric acid for 20 seconds. After applying a uniform layer of adhesive primer on the etched enamel, composite was placed on the base of brackets. The samples were light cured according to the manufacturer&#x2019;s instructions and thermocycled. The SBS was measured. The failure mode was scored using the adhesive remnant index (ARI).
Results: The mean SBS of samples in groups A (high-power LED, metal bracket), B (high-power LED, ceramic bracket), C (conventional LED, metal bracket) and D (conventional LED, ceramic bracket) was 23.1&#xB1;3.69, 10.7&#xB1;2.06, 24.92&#xB1;6.37 and 10.74&#xB1;3.18MPa, respectively. The interaction effect of type of LED unit (high-power/conventional) and bracket type on SBS was not statistically significant (P=0.483). In general, type of LED unit did not affect SBS. Type of bracket significantly affected SBS (P&lt;0.001). The ARI score was not significantly influenced by the interaction between the type of LED unit and bracket.
Conclusions: The obtained SBS is the same for both bracket types by use of high-power and conventional LED light curing units. Regardless of the type of LED unit, SBS of ceramic brackets was significantly lower than that of metal brackets.
&#xD;

&#xA0;</abstract>
    <web_url>https://fid.tums.ac.ir/index.php/fid/article/view/973</web_url>
    <pdf_url>https://fid.tums.ac.ir/index.php/fid/article/download/973/920</pdf_url>
  </Article>
</Articles>
