Original Article

Effect of Storage Period on Dimensional Stability of Alginplus and Hydrogum 5

Abstract

Objectives: This study aimed to evaluate the effect of storage period on dimensional stability of Alginplus and Hydrogum 5.
Materials and Methods: In this in vitro experimental study, 60 impressions were taken of an upper jaw typodont, including 10 impressions for each storage period to be tested (12 minutes, 24 and 120 hours) for each type of alginate. Then, the impressions were stored in an incubator with stable temperature and humidity, and poured using a type III dental stone. Subsequently, the mesiodistal dimension, occlusogingival height, and interarch distance were measured using a digital caliper with an accuracy of 0.01mm. The data were analyzed using ANOVA and t-test (P<0.05).
Results: Alginplus and Hydrogum 5 impressions were not significantly different from the master model after 12 minutes and 24 hours in terms of dimensions (P>0.05). After 120 hours, all dimensions measured on casts were significantly different from those measured on the master model, except for the mesiodistal dimension of the Hydrogum 5 impressions.
Conclusions: At a consistent temperature and humidity, the Alginplus and Hydrogum 5 impressions were dimensionally stable for at least 24 hours.

 

- Alruthea MS. Evaluation of dimensional accuracy material with immediate and delayed pouring. Life Sci J. 2014;11(10):1075-9.

- Nassar U, Aziz T, Flores-Mir C. Dimensional stability of irreversible hydrocolloid impression materials as a function of pouring time: a systematic review. J Prosthet Dent. 2011 Aug;106(2):126-33.

- Hsieh CC, Liu CC, Chen RS. Comparison of physical

properties of light-curing and self-curing dental impression materials. J Formos Med Assoc. 1994 Apr;93(4):294-9.

- Sedda M, Casarotto A, Raustia A, Borracchini A. Effect of storage time on the accuracy of casts made from different irreversible hydrocolloids. J Contemp Dent Pract. 2008 May;9(4):59-66.

- Olvera N, Jones JD. Alternatives to traditional complete dentures. Dent Clin North Am. 2014 Jan;58(1):91-102.

- Rudd KD, Morrow RM, Strunk RR. Accurate alginate impressions. J Prosthet Dent. 1969 Sep;22 (3):294-300.

- Schleier PE, Gardner FM, Nelson SK, Pashley DH. The effect of storage time on the accuracy and dimensional stability of reversible hydrocolloid impression material. J Prosthet Dent. 2001 Sep;86(3): 244-50.

- Farzin M, Panahandeh H. Effect of pouring time and storage temperature on dimensional stability of casts made from irreversible hydrocolloid. J Dent (Tehran). 2010 Fall;7(4):179-84.

- Phoenix RD, Cagna DR, De Freest CF. Stewart's clinical removable partial prosthodontics, Chicago, Quintessence, 2012:133-49.

- Hollenback, GM. A study of the physical properties of elastic impression materials (the linear and over-all accuracy of reversible and irreversible hydrocolloids) Part IV. J. South Calif. St. Dent. Assoc. 1963 Nov;31:204-6.

- Christensen GJ. Marginal fit of gold inlay castings. J Prosthet Dent. 1966 Mar 1;16(2):297-305.

- Mehraban Jahromi S, Yeganeh T, Atashrazm P, Mobayeni MR, Tamizi M, Nematollahi F. Comparing the effect of storage time on dimensional changes of two alginate impression materials (Golchay & Bayer). Res Dent Sci. 2014 Oct;11(3):136-41.

- Kulkarni MM, Thombare RU. Dimensional Changes of Alginate Dental Impression Materials-An Invitro Study. Journal of clinical and diagnostic research: JCDR. 2015 Aug;9(8):ZC98-102.

- Rohanian A, Ommati Shabestari G, Zeighami S, Samadi MJ, Shamshiri AR. Effect of storage time of extended-pour and conventional alginate impressions on dimensional accuracy of casts. J Dent (Tehran). 2014 Nov;11(6):655-64.

- Atashrazm P, Tamizi M, Jahromi SM, Nematollahi F, Heidari A, Jalalian S. The effect of time storage on the dimensional changes of hydrogam 5 alginate. J Res Dent Sci. 2013 Apr; 10(1):17-21.

- Hiraguchi H, Kaketani M, Hirose H, Yoneyama T. The influence of storing alginate impressions sprayed with disinfectant on dimensional accuracy and deformation of maxillary edentulous stone models. Dent Mater. 2010 May;29(3):309-15.

- Wadhwa SS, Mehta R, Duggal N, Vasudeva K. The effect of pouring time on the dimensional accuracy of casts made from different irreversible hydrocolloid impression materials. Contemp Clin Dent. 2013 Jul;4(3):313-8.

- Aoyama N, Hayakawa I, Akiba N, Minakuchi S. Effect of high-molecular-weight sodium alginate on the viscosity and characteristics of alginate impression materials. Prosthodont Res Pract. 2007;6(4):239-45.

- Imbery TA, Nehring J, Janus C, Moon PC. Accuracy and dimensional stability of extended-pour and conventional alginate impression materials. J Am Dent Assoc. 2010 Jan;141(1):32-9.

- Rudd KD, Morrow RM, Strunk RR. Accurate alginate impressions. J Prosthet Dent. 1969 Sep;22 (3):294-300.

- Johnson GH, Chellis KD, Gordon GE, Lepe X. Dimensional stability and detail reproduction of irreversible hydrocolloid and elastomeric impressions disinfected by immersion. J Prosthet Dent. 1998 Apr;79(4):446-53.

- Skinner EW, Hobilt NE. A study of the accuracy of hydrocolloid impressions. J Prosthet Dent. 1956 Jan;6(1):80-6.

- Bayindir F, Yanikoğlu N, Duymuş Z. Thermal and pH changes, and dimensional stability in irreversible hydrocolloid impression material during setting. Dent Mater. 2002 Jun;21(2):200-9.

- Mosharraf R, Nosouhian S, Salehi M. Effect of storage time on dimensional stability of Extended-Pour irreversible hydrocolloid material. J Isfahan

Dent Sch. 2011;7(3):246–55.

- Donovan TE, Chee WW. A review of contemporary impression materials and techniques. Dent Clin North Am. 2004 Apr 30;48(2):445-70.

- Atashrazm P, Valaee N, Mobini M R, Zamani Alavijeh L. Comparison of the Dimensional Changes of Ariadent and Bayer Alginate Impression Materials (Invitro). J Res Dent Sci. 2012 Feb;8(4):168-74.

- Fonte-Boa J, Lanza MD, da Cunha Peixoto RT, Drummond AF, de Sousa EL. Dimensional analysis of alginate molds after storage. Arq Odontol, Belo Horizonte. 2016 Jun;52(2):117-122.

- Saito S, Ichimaru T, Araki Y. Factors affecting dimensional in stability of alginate impressions during immersion in the fixing and disinfectant solutions. Dent Mater. 1998 Dec;17(4):294-300.

- Reddy CG, Gujjari AK, Shambhu HS. Influence of long term storage on the linear dimensional accuracy of improved alginate impressions-an in vitro study. TPDI. 2010;1(2):34-37.

- Todd JA, Oesterle LJ, Newman SM, Shellhart WC. Dimensional changes of extended-pour alginate impression materials. Am J Orthod Dentofacial Orthop. 2013 Apr;143(4 Suppl):S55-63.

- Lee SM, Hou Y, Cho JH, Hwang HS. Dimensional accuracy of digital dental models from cone-beam computed tomography scans of alginate impressions according to time elapsed after the impressions. Am J Orthod Dentofacial Orthop. 2016 Feb;149(2):287-94.

- Jiang T, Lee SM, Hou Y, Chang X, Hwang HS. Evaluation of digital dental models obtained from dental cone-beam computed tomography scan of alginate impressions. Korean J Orthod. 2016 May;46 (3):129-36.

- Rodrigues SB, Augusto CR, Leitune VC, Samuel SM, Collares FM. Influence of delayed pouring on irreversible hydrocolloid properties. Braz Oral Res. 2012 Oct;26(5):404-9.

- Torassian G, Kau CH, English JD, Powers J, Bussa HI, Marie Salas-Lopez A, et al. Digital models vs plaster models using alginate and alginate substitute materials. Angle Orthod. 2010 Jul;80(4): 474-81.

- Alcan T, Ceylanoğlu C, Baysal B. The relationship between digital model accuracy and time-dependent deformation of alginate impressions. Angle Orthod. 2009 Jan;79(1):30-6.

- Walker MP, Burckhard J, Mitts DA, Williams KB. Dimensional change over time of extended-storage alginate impression materials. Angle Orthod. 2010 Nov;80(6):1110-5.

- Eriksson A, Ockert-Eriksson G, Lockowandt P. Accuracy of irreversible hydrocolloids (alginates) for fixed prosthodontics. A comparison between irreversible hydrocolloid, reversible hydrocolloid, and addition silicone for use in the syringe-tray technique. Eur J Oral Sci. 1998 Apr;106(2p1):651-60.

- Taylor RL, Wright PS, Maryan C. Disinfection procedures: their effect on the dimensional accuracy and surface quality of irreversible hydrocolloid impression materials and gypsum casts. Dent Mater. 2002 Mar;18(2):103-10.

- Nassar U, Hussein B, Oko A, Carey JP, Flores-Mir C. Dimensional accuracy of 2 irreversible hydrocolloid alternative impression materials with immediate and delayed pouring. J Can Dent Assoc. 2012;78(78):c2.

Files
IssueVol 14, No 1 (2017) QRcode
SectionOriginal Article
Keywords
Alginate Alginplus Hydrogum Dimensional stability Impression

Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
How to Cite
1.
Aalaei S, Ganj-Khanloo R, Gholami F. Effect of Storage Period on Dimensional Stability of Alginplus and Hydrogum 5. Front Dent. 2017;14(1):31-39.