Dimensional Changes of 3-Unit Implant-Supported Zirconia Frameworks of Two CAD/CAM Systems from Scanning to Sintering
Abstract
Objectives: Internal fit of implant frameworks is an important factor determining the long-term success of dental implant restorations. This in-vitro study aimed to evaluate dimensional changes of implant-supported zirconia frameworks fabricated by two computer-aided design/computer-aided manufacturing (CAD/CAM) systems from scanning to sintering.
Materials and Methods: A master model of a three-unit fixed partial denture was fabricated with two implant abutments. In each CAD/CAM system (AmannGirrbach and Zirkonzahn), the master model was scanned 12 times, and data were saved as Standard Transformation Language files (scanning groups). Using semi-sintered zirconia, 12 real-size frameworks (milling groups) and 12 enlarged frameworks, were sintered (sintering groups) and made by each system. Dimensions of the master model and frameworks in each phase were measured. Dimensional changes (compared to the master model) were calculated. Data were analyzed using repeated measures analysis of variance, independent t-test, and paired sample t-test (α=0.05).
Results: Comparison of the two CAD/CAM systems revealed that although dimensional changes were greater in the Zirkonzahn system in the milling phase, they were greater in the AmannGirrbach system in the sintering phase. Evaluation of fabrication phases in each system revealed greater dimensional changes in the milling phase compared to other phases in the Zirkonzahn system (P<0.05). However, in the AmannGirrbach system, the values were not significantly different between the milling and sintering phases (P>0.05).
Conclusion: Within the limitations of this study, the results showed that fabrication phases, type of CAD/CAM system, and abutment size had significant effects on dimensional changes.
Pietrabissa R, Contro R, Quaglini V, Soncini M, Gionso L, Simion M. Experimental and computational approach for the evaluation of the biomechanical effects of dental bridge misfit. J Biomech. 2000 Nov;33(11):1489-95.
De Boever AL, Keersmaekers K, Vanmaele G, Kerschbaum T, Theuniers G, De Boever JA. Prosthetic complications in fixed endosseous implant-borne reconstructions after an observations period of at least 40 months. J Oral Rehabil. 2006 Nov;33(11):833-9.
Kreissl ME, Gerds T, Muche R, Heydecke G, Strub JR. Technical complications of implant-supported fixed partial dentures in partially edentulous cases after an average observation period of 5 years. Clin Oral Implants Res. 2007 Dec;18(6):720-6.
Abduo J, Bennani V, Waddell N, Lyons K, Swain M. Assessing the fit of implant fixed prostheses: a critical review. Int J Oral Maxillofac Implants. 2010 May-Jun;25(3):506-15.
Karl M, Taylor TD. Effect of material selection on the passivity of fit of implant-supported restorations created with computer-aided design/computer-assisted manufacture. Int J Oral Maxillofac Implants. 2011 Jul-Aug;26(4):739-45.
Branemark PI. Osseointegration and its experimental background. J Prosthet Dent. 1983 Sep;50(3):399-410.
Schwarz MS. Mechanical complications of dental implants. Clin Oral Implants Res. 2000;11 Suppl 1:156-8.
Romero GG, Engelmeier R, Powers JM, Canterbury AA. Accuracy of three corrective techniques for implant bar fabrication. J Prosthet Dent. 2000 Dec;84(6):602-7.
Sahin S, Cehreli MC, Yalcin E. The influence of functional forces on the biomechanics of implant-supported prostheses--a review. J Dent. 2002 Sep-Nov;30(7-8):271-82.
Kunavisarut C, Lang LA, Stoner BR, Felton DA. Finite element analysis on dental implant-supported prostheses without passive fit. J Prosthodont. 2002 Mar;11(1):30-40.
Winter W, Mohrle S, Holst S, Karl M. Bone loading caused by different types of misfits of implant-supported fixed dental prostheses: a three-dimensional finite element analysis based on experimental results. Int J Oral Maxillofac Implants. 2010 Sep-Oct;25(5):947-52.
Bacchi A, Consani RL, Mesquita MF, dos Santos MB. Stress distribution in fixed-partial prosthesis and peri-implant bone tissue with different framework materials and vertical misfit levels: a three-dimensional finite element analysis. J Oral Sci. 2013 Sep;55(3):239-44.
Erkmen E, Meric G, Kurt A, Tunc Y, Eser A. Biomechanical comparison of implant retained fixed partial dentures with fiber reinforced composite versus conventional metal frameworks: a 3D FEA study. J Mech Behav Biomed Mater. 2011 Jan;4(1):107-16.
Beuer F, Schweiger J, Edelhoff D. Digital dentistry: an overview of recent developments for CAD/CAM generated restorations. Br Dent J. 2008 May 10;204(9):505-11.
Kohorst P, Junghanns J, Dittmer MP, Borchers L, Stiesch M. Different CAD/CAM-processing routes for zirconia restorations: influence on fitting accuracy. Clin Oral Investig. 2011 Aug;15(4):527-36.
Bindl A, Mormann WH. Fit of all-ceramic posterior fixed partial denture frameworks in vitro. Int J Periodontics Restorative Dent. 2007 Dec;27(6):567-75.
Att W, Komine F, Gerds T, Strub JR. Marginal adaptation of three different zirconium dioxide three-unit fixed dental prostheses. J Prosthet Dent. 2009 Apr;101(4):239-47.
Gonzalo E, Suarez MJ, Serrano B, Lozano JF. A comparison of the marginal vertical discrepancies of zirconium and metal ceramic posterior fixed dental prostheses before and after cementation. J Prosthet Dent. 2009 Dec;102(6):378-84.
Karatasli O, Kursoglu P, Capa N, Kazazoglu E. Comparison of the marginal fit of different coping materials and designs produced by computer aided manufacturing systems. Dent Mater J. 2011;30(1):97-102.
Kohorst P, Brinkmann H, Dittmer MP, Borchers L, Stiesch M. Influence of the veneering process on the marginal fit of zirconia fixed dental prostheses. J Oral Rehabil. 2010 Apr;37(4):283-91.
Kohorst P, Brinkmann H, Li J, Borchers L, Stiesch M. Marginal accuracy of four-unit zirconia fixed dental prostheses fabricated using different computer-aided design/computer-aided manufacturing systems. Eur J Oral Sci. 2009 Jun;117(3):319-25.
Vigolo P, Fonzi F. An in vitro evaluation of fit of zirconium-oxide-based ceramic four-unit fixed partial dentures, generated with three different CAD/CAM systems, before and after porcelain firing cycles and after glaze cycles. J Prosthodont. 2008 Dec;17(8):621-6.
Pak HS, Han JS, Lee JB, Kim SH, Yang JH. Influence of porcelain veneering on the marginal fit of Digident and Lava CAD/CAM zirconia ceramic crowns. J Adv Prosthodont. 2010 Jun;2(2):33-8. PubMed PMID: 21165185.
Prasad R, Al-Kheraif AA. Three-dimensional accuracy of CAD/CAM titanium and ceramic superstructures for implant abutments using spiral scan microtomography. Int J Prosthodont. 2013 Sep-Oct;26(5):451-7.
Aboushelib MN, Elmahy WA, Ghazy MH. Internal adaptation, marginal accuracy and microleakage of a pressable versus a machinable ceramic laminate veneers. J Dent. 2012 Aug;40(8):670-7.
Matta RE, Schmitt J, Wichmann M, Holst S. Circumferential fit assessment of CAD/CAM single crowns--a pilot investigation on a new virtual analytical protocol. Quintessence Int. 2012 Oct;43(9):801-9.
Moldovan O, Luthardt RG, Corcodel N, Rudolph H. Three-dimensional fit of CAD/CAM-made zirconia copings. Dent Mater. 2011 Dec;27(12):1273-8.
Rungruanganunt P, Kelly JR, Adams DJ. Two imaging techniques for 3D quantification of pre-cementation space for CAD/CAM crowns. J Dent. 2010 Dec;38(12):995-1000.
Abduo J, Lyons K, Waddell N, Bennani V, Swain M. A comparison of fit of CNC-milled titanium and zirconia frameworks to implants. Clin Implant Dent Relat Res. 2012 May;14 Suppl 1:e20-9.
Karl M, Graef F, Wichmann M, Krafft T. Passivity of fit of CAD/CAM and copy-milled frameworks, veneered frameworks, and anatomically contoured, zirconia ceramic, implant-supported fixed prostheses. J Prosthet Dent. 2012 Apr;107(4):232-8.
Al-Fadda SA, Zarb GA, Finer Y. A comparison of the accuracy of fit of 2 methods for fabricating implant-prosthodontic frameworks. Int J Prosthodont. 2007 Mar-Apr;20(2):125-31.
Almasri R, Drago CJ, Siegel SC, Hardigan PC. Volumetric misfit in CAD/CAM and cast implant frameworks: a university laboratory study. J Prosthodont. 2011 Jun;20(4):267-74.
Hjalmarsson L, Ortorp A, Smedberg JI, Jemt T. Precision of fit to implants: a comparison of Cresco and Procera(R) implant bridge frameworks. Clin Implant Dent Relat Res. 2010 Dec;12(4):271-80.
Jemt T, Back T, Petersson A. Precision of CNC-milled titanium frameworks for implant treatment in the edentulous jaw. Int J Prosthodont. 1999 May-Jun;12(3):209-15.
Sierraalta M, Vivas JL, Razzoog ME, Wang RF. Precision of fit of titanium and cast implant frameworks using a new matching formula. Int J Dent. 2012;2012:374315.
Anunmana C, Charoenchitt M, Asvanund C. Gap comparison between single crown and three-unit bridge zirconia substructures. J Adv Prosthodont. 2014 Aug;6(4):253-8.
Grenade C, Mainjot A, Vanheusden A. Fit of single tooth zirconia copings: comparison between various manufacturing processes. J Prosthet Dent. 2011 Apr;105(4):249-55.
Bornemann G, Lemelson S, Luthardt R. Innovative method for the analysis of the internal 3D fitting accuracy of Cerec-3 crowns. Int J Comput Dent. 2002 Apr-Jul;5(2-3):177-82.
Tinschert J, Natt G, Hassenpflug S, Spiekermann H. Status of current CAD/CAM technology in dental medicine. Int J Comput Dent. 2004 Jan;7(1):25-45.
Files | ||
Issue | Vol 16, No 3 (2019) | |
Section | Original Article | |
DOI | https://doi.org/10.18502/fid.v16i3.1591 | |
Keywords | ||
Zirconia CAD/CAM Scanning Milling |
Rights and permissions | |
This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License. |