Abstract

Objectives: Some small defects may remain in the impression after making a two-step putty-light body impression. The aim of this study was to evaluate and compare the dimensional accuracy of 2-step and relined 2-step (3-step) putty-light body impressions.

Materials and Methods: In this in vitro study, 30 impressions were made with putty, light body, and extra-light body addition silicone materials using the 2-step and 3-step impression techniques (N=15). An epoxy resin master model was made duplicating a maxillary typodont with left first premolar and first molar teeth prepared with a shoulder finish line and truncated pyramidal-shaped indices in the mid-palate and third molar sites. In addition to creating a reference digital model by scanning the master model, 30 master casts were scanned to produce digital models. The anteroposterior (AP) and cross-sectional (CS) dimensional accuracy of the models were compared with the master model using linear measurements. Moreover, tooth size measurements were made and compared using the root mean square (RMS). Two-sample t-test was applied to analyze the data (α=0.05).

Results: The mean AP and RMS differences between the two study groups were not significant (P>0.05). However, the CS difference between the two groups was significant (P<0.001), and the 3-step impression technique showed smaller discrepancies in comparison to the master model.

Conclusion: There was no significant difference in accuracy of the two techniques for single-unit and multiple-unit preparations. The 3-step impression technique had a higher CS dimensional accuracy.

1. Chugh A, Arora A, Singh VP. Accuracy of different putty-wash impression techniques with various spacer thickness. Int J Clin Pediatr Dent. 2012 Jan;5(1):33-8.
2. Naumovski B, Kapushevska B. Dimensional stability and accuracy of silicone-based impression materials using different impression techniques - A literature review. Pril (Makedon Akad Nauk Umet Odd Med Nauki). 2017 Sep;38(2):131-138.
3. Caputi S, Varvara G. Dimensional accuracy of resultant casts made by a monophase, one-step and two-step, and a novel two-step putty/light-body impression technique: an in vitro study. J Prosthet Dent. 2008 Apr;99(4):274-81.
4. Varvara G, Murmura G, Sinjari B, Cardelli P, Caputi S. Evaluation of defects in surface detail for monophase, 2-phase, and 3-phase impression techniques: an in vitro study. J Prosthet Dent. 2015 Feb;113(2):108-13.
5. Rau CT, Olafsson VG, Delgado AJ, Ritter AV, Donovan TE. The quality of fixed prosthodontic impressions: An assessment of crown and bridge impressions received at commercial laboratories. J Am Dent Assoc. 2017 Sep;148(9):654-660.
6. Rau CT, Olafsson VG, Delgado AJ, Ritter AV, Donovan TE. The quality of fixed prosthodontic impressions: An assessment of crown and bridge impressions received at commercial laboratories. J Am Dent Assoc. 2017 Sep;148(9):654-660.
7. Podshadley AG, Dilts WE, Neiman R, Ellison E. Accuracy of relined mercaptan-rubber impressions. J Prosthet Dent. 1970 Nov;24(5):503-11.
8. Punj A, Bompolaki D, Garaicoa J. Dental impression materials and techniques. Dent Clin North Am. 2017 Oct;61(4):779-796.
9. Kumar MP, Patil SG, Dheeraj B, Reddy K, Goel D, Krishna G. A comparison of accuracy of matrix impression system with putty reline technique and multiple mix technique: An in vitro study. J Int Oral Health. 2015 Jun;7(6):48-53.
10. Ender A, Zimmermann M, Attin T, Mehl A. In vivo precision of conventional and digital methods for obtaining quadrant dental impressions. Clin Oral Investig. 2016 Sep;20(7):1495-504.
11. Stober T, Johnson GH, Schmitter M. Accuracy of the newly formulated vinyl siloxanether elastomeric impression material. J Prosthet Dent. 2010 Apr;103(4):228-39.
12. Arora M, Kohli S, Kalsi R. Influence of custom trays, dual-arch passive, flexed trays and viscosities of elastomeric impression materials on working dies. J Clin Diagn Res. 2016 May;10(5):ZC112-6.
13. Rudolph H, Quaas S, Haim M, Preißler J, Walter MH, Koch R, et al. Randomized controlled clinical trial on the three-dimensional accuracy of fast-set impression materials. Clin Oral Investig. 2013 Jun;17(5):1397-406.
14. Ozcelik TB, Ozcan I, Ozan O. Digital evaluation of the dimensional accuracy of four different implant impression techniques. Niger J Clin Pract. 2018 Oct;21(10):1247-1253.
15. Bomberg TJ, Hatch RA. Correction of defective impressions by the selective addition of impression material. J Prosthet Dent. 1984 Jul;52(1):38-40.
16. Sabouri A, Sadr SJ. The effect of rewash on putty-wash impression technique in fixed prosthodontics. Research J Biol Sci. 2007;2(7):702-5.
IssueVol 21 (Continuously Published Article-Based) QRcode
SectionOriginal Article
DOI https://doi.org/10.18502/fid.v21i17.15550
Keywords
two-step impression putty-wash light body fixed prosthodontics relined impression

Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
How to Cite
1.
Jafari A, Mombeini E, Payaminia L, Beyabanaki E, Tahmasebi R. Dimensional Accuracy of Two-Step Impressions Relined with Extra-Light Addition Silicone Material. Front Dent. 2024;21.